US-OR North America Updated 2026-08-20

United States (Oregon) Geothermal Screening

Geothermal screening assessment identifies 40.3% prospective land reaching 185°C by 5.5 km depth in United States (Oregon).

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km High Potential
40.3%

Primary baseline screening criterion

Shallowest Depth to 200°C Very Shallow
3 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
271.4 °C

Maximum modeled temperature

Typical Geothermal Gradient Volcanic / Rift
62.8 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area Moderate Distance
69.2%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
173.9 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 9.9% 30.2% 43.6% 57.8% 78.5% 83.7%
175°C 8.7% 20.9% 34.3% 54.2% 60.6% 68.2%
200°C 7.1% 17% 27.7% 38% 46.9% 60.1%
225°C 5.5% 14% 23.7% 35.3% 38.8% 55.2%
250°C 4.1% 11.6% 17.5% 25.4% 32% 36.2%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
254 799 km² 100%
2 Reaches 185°C by 5.5 km
102 684 km² 40.3%
3 ...and within 50 km transmission
71 057 km² 27.9%
4 ...and within 100 km town
61 313 km² 24.2%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 5.8 km
Best 10th Percentile Depth to 200°C 3.9 km
Median Temperature at 5 km Depth 219.6 °C
Best 10th Percentile Temp at 5 km 249.6 °C
Median Sediment Thickness 0.6 km
Sediment / Hard-Rock Well Share 43.6%
Territory Under 1 km Sediment Cover 85.6%
Lithostatic Pressure at 5 km Depth 137.9 MPa
Moho Crustal Discontinuity Depth 34.4 km
Thermal Lithosphere Thickness 78 km
Curie Temperature Isotherm Depth 15.5 km
Model Temperature Spread Uncertainty (200°C) ±1 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 8 602 km
Land Area Within 25 km of Grid 52.4%
Land Area Within 50 km of Grid 69.2%
Land Area Within 100 km of Grid 81.3%
Average Proximity to Nearest Substation / Line 18.5 km
Urban Centers (>10,000 Population) 170
Total Urban Population 13.7 M
Prospective Resource Colocated Near Demand (>1M Pop) 27.3%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 64.5% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 72.5% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of United States (Oregon) across 11 standardized geothermal indicators

United States (Oregon) Rank Global Peer Spread
Shallowest 200°C depth
3 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 71th percentile
Peak temp at 5 km
271.4 °C Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 69th percentile
Prospective land area (>185°C at 5.5 km)
40.3% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 67th percentile
Stored heat in-place (3-7 km)
173.9 ZJ Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 70th percentile
Typical geothermal gradient
62.8 °C/km Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 90th percentile
Grid proximity (<50 km)
69.2% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 69th percentile
Thin sediment coverage (<1 km)
85.6% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 86th percentile
Curie isotherm depth
15.5 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 66th percentile
Moho crustal thickness
34.4 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 38th percentile
Model temperature uncertainty spread
±0.9 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 67th percentile
Urban demand colocation
78.1% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 62th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for United States (Oregon)?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for United States (Oregon) are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: United States (Oregon)

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for United States (Oregon) indicates volcanic_arc geological controls governing subsurface heat transport, yielding 40.3% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across United States (Oregon) shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 69.2% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by volcanic arc dynamics with median sediment thickness of 0.6 km and crustal thickness of 34.4 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 173.9 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, United States (Oregon) demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for United States (Oregon) is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 2 831 model cells (land area: 254 799 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.