NG Africa Updated 2026-08-20

Nigeria Geothermal Screening

Geothermal screening assessment identifies 12.6% prospective land reaching 185°C by 5.5 km depth in Nigeria.

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
12.6%

Primary baseline screening criterion

Shallowest Depth to 200°C Deep Target
5 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Direct Heat
186.6 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
34.9 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
82%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
302.5 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 1.6% 3.7% 6.9% 9.2% 12.1% 12.6%
175°C 1.7% 2.6% 5% 6.4% 9% 11%
200°C 1% 1.9% 2.9% 3.7% 5.4% 6.1%
225°C 0.2% 0.6% 0.8% 1.3% 1.7% 1.9%
250°C

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
923 768 km² 100%
2 Reaches 185°C by 5.5 km
116 395 km² 12.6%
3 ...and within 50 km transmission
95 444 km² 10.3%
4 ...and within 100 km town
88 590 km² 9.1%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 7.6 km
Best 10th Percentile Depth to 200°C 5.5 km
Median Temperature at 5 km Depth 137 °C
Best 10th Percentile Temp at 5 km 168.8 °C
Median Sediment Thickness 3.9 km
Sediment / Hard-Rock Well Share 42.5%
Territory Under 1 km Sediment Cover 39.3%
Lithostatic Pressure at 5 km Depth 138.7 MPa
Moho Crustal Discontinuity Depth 33.2 km
Thermal Lithosphere Thickness 95 km
Curie Temperature Isotherm Depth 27.8 km
Model Temperature Spread Uncertainty (200°C) ±0.8 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 18 019 km
Land Area Within 25 km of Grid 70.3%
Land Area Within 50 km of Grid 82%
Land Area Within 100 km of Grid 96.4%
Average Proximity to Nearest Substation / Line 34.9 km
Urban Centers (>10,000 Population) 214
Total Urban Population 18 M
Prospective Resource Colocated Near Demand (>1M Pop) 56.9%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 20.2% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 22.7% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Nigeria across 11 standardized geothermal indicators

Nigeria Rank Global Peer Spread
Shallowest 200°C depth
5 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Peak temp at 5 km
186.6 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 35th percentile
Prospective land area (>185°C at 5.5 km)
12.6% Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 21th percentile
Stored heat in-place (3-7 km)
302.5 ZJ Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 78th percentile
Typical geothermal gradient
34.9 °C/km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 50th percentile
Grid proximity (<50 km)
82% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 82th percentile
Thin sediment coverage (<1 km)
39.3% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 39th percentile
Curie isotherm depth
27.8 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 39th percentile
Moho crustal thickness
33.2 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 40th percentile
Model temperature uncertainty spread
±0.6 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 66th percentile
Urban demand colocation
33.2% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 71th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Nigeria?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Nigeria are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Nigeria

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Nigeria indicates sedimentary_rift geological controls governing subsurface heat transport, yielding 12.6% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Nigeria shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 82% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by sedimentary rift dynamics with median sediment thickness of 3.9 km and crustal thickness of 33.2 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 302.5 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Nigeria demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Nigeria is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 10 264 model cells (land area: 923 768 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier