GW Africa Updated 2026-08-20

Guinea-Bissau Geothermal Screening

Geothermal screening assessment identifies 13.6% prospective land reaching 185°C by 5.5 km depth in Guinea-Bissau.

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
13.6%

Primary baseline screening criterion

Shallowest Depth to 200°C Deep Target
6 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Direct Heat
182.2 °C

Maximum modeled temperature

Typical Geothermal Gradient Continental Normal
29.1 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
82.5%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
11.3 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 2.5% 3.7% 7.2% 9.6% 12.4% 13.2%
175°C 1.7% 2.8% 4.5% 6% 8.2% 10%
200°C 0.9% 1.5% 2.6% 3.2% 4.8% 5.1%
225°C 0.2% 0.4% 0.5% 0.8% 1.1% 1.2%
250°C

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
36 125 km² 100%
2 Reaches 185°C by 5.5 km
4 913 km² 13.6%
3 ...and within 50 km transmission
4 053 km² 11.2%
4 ...and within 100 km town
3 587 km² 10.4%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 8.2 km
Best 10th Percentile Depth to 200°C 7 km
Median Temperature at 5 km Depth 125.1 °C
Best 10th Percentile Temp at 5 km 163.9 °C
Median Sediment Thickness 3.8 km
Sediment / Hard-Rock Well Share 24.3%
Territory Under 1 km Sediment Cover 33.3%
Lithostatic Pressure at 5 km Depth 134.3 MPa
Moho Crustal Discontinuity Depth 30.8 km
Thermal Lithosphere Thickness 69.6 km
Curie Temperature Isotherm Depth 25 km
Model Temperature Spread Uncertainty (200°C) ±1.5 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 8 345 km
Land Area Within 25 km of Grid 67.9%
Land Area Within 50 km of Grid 82.5%
Land Area Within 100 km of Grid 94.3%
Average Proximity to Nearest Substation / Line 25.9 km
Urban Centers (>10,000 Population) 48
Total Urban Population 6 M
Prospective Resource Colocated Near Demand (>1M Pop) 58.1%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 21.8% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 24.5% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Guinea-Bissau across 11 standardized geothermal indicators

Guinea-Bissau Rank Global Peer Spread
Shallowest 200°C depth
6 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 29th percentile
Peak temp at 5 km
182.2 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 33th percentile
Prospective land area (>185°C at 5.5 km)
13.6% Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 23th percentile
Stored heat in-place (3-7 km)
11.3 ZJ Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 33th percentile
Typical geothermal gradient
29.1 °C/km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 42th percentile
Grid proximity (<50 km)
82.5% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 82th percentile
Thin sediment coverage (<1 km)
33.3% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 33th percentile
Curie isotherm depth
25 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 45th percentile
Moho crustal thickness
30.8 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 45th percentile
Model temperature uncertainty spread
±1.6 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 79th percentile
Urban demand colocation
64.3% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 71th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Guinea-Bissau?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Guinea-Bissau are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Guinea-Bissau

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Guinea-Bissau indicates sedimentary_rift geological controls governing subsurface heat transport, yielding 13.6% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Guinea-Bissau shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 82.5% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by sedimentary rift dynamics with median sediment thickness of 3.8 km and crustal thickness of 30.8 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 11.3 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Guinea-Bissau demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Guinea-Bissau is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 401 model cells (land area: 36 125 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.