TW-ER Asia Pacific Updated 2026-08-20

Taiwan (Eastern Longitudinal Valley) Geothermal Screening

Geothermal screening assessment identifies 40.3% prospective land reaching 185°C by 5.5 km depth in Taiwan (Eastern Longitudinal Valley).

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km High Potential
40.3%

Primary baseline screening criterion

Shallowest Depth to 200°C Shallow
3.5 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Superhot
309.5 °C

Maximum modeled temperature

Typical Geothermal Gradient Volcanic / Rift
53.7 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area Moderate Distance
72.6%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
91.8 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 14.4% 31.5% 48.7% 71.4% 93.9% 100%
175°C 15.2% 27.2% 45.4% 56.6% 73.3% 100%
200°C 11% 24.3% 39.6% 50.6% 73.4% 73.4%
225°C 10.4% 21.1% 30.1% 46.1% 56.3% 69.2%
250°C 8.9% 15.3% 24% 36.3% 47.5% 56.8%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
12 000 km² 100%
2 Reaches 185°C by 5.5 km
4 836 km² 40.3%
3 ...and within 50 km transmission
3 511 km² 29.3%
4 ...and within 100 km town
3 023 km² 25%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 6.2 km
Best 10th Percentile Depth to 200°C 4.3 km
Median Temperature at 5 km Depth 220.4 °C
Best 10th Percentile Temp at 5 km 277.3 °C
Median Sediment Thickness 0.5 km
Sediment / Hard-Rock Well Share 11.4%
Territory Under 1 km Sediment Cover 89.2%
Lithostatic Pressure at 5 km Depth 134.9 MPa
Moho Crustal Discontinuity Depth 32.1 km
Thermal Lithosphere Thickness 73.2 km
Curie Temperature Isotherm Depth 15.3 km
Model Temperature Spread Uncertainty (200°C) ±0.9 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 2 730 km
Land Area Within 25 km of Grid 63.7%
Land Area Within 50 km of Grid 72.6%
Land Area Within 100 km of Grid 83.5%
Average Proximity to Nearest Substation / Line 19.2 km
Urban Centers (>10,000 Population) 43
Total Urban Population 3.3 M
Prospective Resource Colocated Near Demand (>1M Pop) 74.9%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 64.5% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 72.5% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Taiwan (Eastern Longitudinal Valley) across 11 standardized geothermal indicators

Taiwan (Eastern Longitudinal Valley) Rank Global Peer Spread
Shallowest 200°C depth
3.5 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 64th percentile
Peak temp at 5 km
309.5 °C Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 84th percentile
Prospective land area (>185°C at 5.5 km)
40.3% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 67th percentile
Stored heat in-place (3-7 km)
91.8 ZJ Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 61th percentile
Typical geothermal gradient
53.7 °C/km Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 77th percentile
Grid proximity (<50 km)
72.6% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 73th percentile
Thin sediment coverage (<1 km)
89.2% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 89th percentile
Curie isotherm depth
15.3 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 66th percentile
Moho crustal thickness
32.1 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 42th percentile
Model temperature uncertainty spread
±0.9 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 67th percentile
Urban demand colocation
56.5% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 78th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Taiwan (Eastern Longitudinal Valley)?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Taiwan (Eastern Longitudinal Valley) are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Taiwan (Eastern Longitudinal Valley)

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Taiwan (Eastern Longitudinal Valley) indicates volcanic_arc geological controls governing subsurface heat transport, yielding 40.3% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Taiwan (Eastern Longitudinal Valley) shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 72.6% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by volcanic arc dynamics with median sediment thickness of 0.5 km and crustal thickness of 32.1 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 91.8 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Taiwan (Eastern Longitudinal Valley) demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Taiwan (Eastern Longitudinal Valley) is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 133 model cells (land area: 12 000 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier