AU Asia Pacific Updated 2026-08-20

Australia Geothermal Screening

Geothermal screening assessment identifies 15% prospective land reaching 185°C by 5.5 km depth in Australia.

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
15%

Primary baseline screening criterion

Shallowest Depth to 200°C Deep Target
5.2 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
221.4 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
40.7 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
86.2%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
2147.9 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 3.5% 7.1% 11.1% 15.8% 21.5% 21.9%
175°C 2.1% 5% 8.6% 11.8% 16.4% 17.9%
200°C 2.1% 3.7% 6.4% 9.3% 12.8% 14.1%
225°C 1.1% 2.5% 4.5% 6.3% 7% 10%
250°C 0.7% 1.2% 2% 2.8% 3.7% 4.1%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
7 692 024 km² 100%
2 Reaches 185°C by 5.5 km
1 153 804 km² 15%
3 ...and within 50 km transmission
994 579 km² 12.9%
4 ...and within 100 km town
837 233 km² 11.8%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 7.5 km
Best 10th Percentile Depth to 200°C 6.2 km
Median Temperature at 5 km Depth 166.4 °C
Best 10th Percentile Temp at 5 km 202.3 °C
Median Sediment Thickness 1.1 km
Sediment / Hard-Rock Well Share 37.7%
Territory Under 1 km Sediment Cover 50%
Lithostatic Pressure at 5 km Depth 136.8 MPa
Moho Crustal Discontinuity Depth 31.4 km
Thermal Lithosphere Thickness 69.9 km
Curie Temperature Isotherm Depth 20.3 km
Model Temperature Spread Uncertainty (200°C) ±1.5 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 43 119 km
Land Area Within 25 km of Grid 68.6%
Land Area Within 50 km of Grid 86.2%
Land Area Within 100 km of Grid 95.7%
Average Proximity to Nearest Substation / Line 18.3 km
Urban Centers (>10,000 Population) 710
Total Urban Population 70.5 M
Prospective Resource Colocated Near Demand (>1M Pop) 27.1%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 24% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 27% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Australia across 11 standardized geothermal indicators

Australia Rank Global Peer Spread
Shallowest 200°C depth
5.2 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 40th percentile
Peak temp at 5 km
221.4 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 49th percentile
Prospective land area (>185°C at 5.5 km)
15% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 25th percentile
Stored heat in-place (3-7 km)
2147.9 ZJ Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 99th percentile
Typical geothermal gradient
40.7 °C/km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 58th percentile
Grid proximity (<50 km)
86.2% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 86th percentile
Thin sediment coverage (<1 km)
50% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 50th percentile
Curie isotherm depth
20.3 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 55th percentile
Moho crustal thickness
31.4 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Model temperature uncertainty spread
±0.7 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 73th percentile
Urban demand colocation
50.6% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 68th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Australia?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Australia are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Australia

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Australia indicates granite_radiogenic geological controls governing subsurface heat transport, yielding 15% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Australia shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 86.2% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by granite radiogenic dynamics with median sediment thickness of 1.1 km and crustal thickness of 31.4 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 2147.9 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Australia demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Australia is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 85 467 model cells (land area: 7 692 024 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier