KR Asia Pacific Updated 2026-08-20

South Korea Geothermal Screening

Geothermal screening assessment identifies 14.1% prospective land reaching 185°C by 5.5 km depth in South Korea.

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
14.1%

Primary baseline screening criterion

Shallowest Depth to 200°C Shallow
4 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
208.6 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
40 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
89%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
32 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 2.5% 5.9% 10.1% 12.9% 15.4% 19.6%
175°C 2.2% 3.8% 7.4% 10.8% 11.4% 16.7%
200°C 1.8% 3.2% 5.1% 6% 9.7% 11.6%
225°C 0.8% 1.9% 3.1% 4.3% 4.6% 6%
250°C 0.2% 0.5% 0.8% 1% 1.3% 1.6%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
100 210 km² 100%
2 Reaches 185°C by 5.5 km
14 130 km² 14.1%
3 ...and within 50 km transmission
12 576 km² 12.5%
4 ...and within 100 km town
11 916 km² 11.1%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 6.7 km
Best 10th Percentile Depth to 200°C 4.5 km
Median Temperature at 5 km Depth 149 °C
Best 10th Percentile Temp at 5 km 181.9 °C
Median Sediment Thickness 1.4 km
Sediment / Hard-Rock Well Share 29.3%
Territory Under 1 km Sediment Cover 67.1%
Lithostatic Pressure at 5 km Depth 135.2 MPa
Moho Crustal Discontinuity Depth 32.2 km
Thermal Lithosphere Thickness 93.6 km
Curie Temperature Isotherm Depth 24.7 km
Model Temperature Spread Uncertainty (200°C) ±1.1 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 7 274 km
Land Area Within 25 km of Grid 74.7%
Land Area Within 50 km of Grid 89%
Land Area Within 100 km of Grid 95%
Average Proximity to Nearest Substation / Line 21.9 km
Urban Centers (>10,000 Population) 56
Total Urban Population 13.3 M
Prospective Resource Colocated Near Demand (>1M Pop) 23.7%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 22.6% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 25.4% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of South Korea across 11 standardized geothermal indicators

South Korea Rank Global Peer Spread
Shallowest 200°C depth
4 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 57th percentile
Peak temp at 5 km
208.6 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Prospective land area (>185°C at 5.5 km)
14.1% Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 24th percentile
Stored heat in-place (3-7 km)
32 ZJ Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 47th percentile
Typical geothermal gradient
40 °C/km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 57th percentile
Grid proximity (<50 km)
89% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 89th percentile
Thin sediment coverage (<1 km)
67.1% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 67th percentile
Curie isotherm depth
24.7 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 46th percentile
Moho crustal thickness
32.2 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 42th percentile
Model temperature uncertainty spread
±1.6 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 55th percentile
Urban demand colocation
47.9% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 60th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for South Korea?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for South Korea are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: South Korea

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for South Korea indicates granite_radiogenic geological controls governing subsurface heat transport, yielding 14.1% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across South Korea shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 89% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by granite radiogenic dynamics with median sediment thickness of 1.4 km and crustal thickness of 32.2 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 32 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, South Korea demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for South Korea is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 1 113 model cells (land area: 100 210 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier