UZ Central Asia Updated 2026-08-20

Uzbekistan Geothermal Screening

Geothermal screening assessment identifies 13.6% prospective land reaching 185°C by 5.5 km depth in Uzbekistan.

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
13.6%

Primary baseline screening criterion

Shallowest Depth to 200°C Shallow
4.5 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
211.8 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
33.2 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
91.9%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
127.7 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 3.3% 5.6% 9.3% 13.6% 15.1% 21.1%
175°C 1.8% 4.9% 7% 10.2% 12.5% 15.2%
200°C 1.4% 3.3% 5.1% 7.1% 8% 11.3%
225°C 0.9% 1.9% 3.1% 4% 6% 6.8%
250°C 0.3% 0.6% 0.9% 1.2% 1.7% 2.1%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
447 400 km² 100%
2 Reaches 185°C by 5.5 km
60 846 km² 13.6%
3 ...and within 50 km transmission
55 917 km² 12.5%
4 ...and within 100 km town
49 772 km² 10.7%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 7.2 km
Best 10th Percentile Depth to 200°C 5.4 km
Median Temperature at 5 km Depth 157.2 °C
Best 10th Percentile Temp at 5 km 183.9 °C
Median Sediment Thickness 2.2 km
Sediment / Hard-Rock Well Share 34.9%
Territory Under 1 km Sediment Cover 15.4%
Lithostatic Pressure at 5 km Depth 138.5 MPa
Moho Crustal Discontinuity Depth 34.3 km
Thermal Lithosphere Thickness 92.4 km
Curie Temperature Isotherm Depth 27.2 km
Model Temperature Spread Uncertainty (200°C) ±0.8 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 12 917 km
Land Area Within 25 km of Grid 73.2%
Land Area Within 50 km of Grid 91.9%
Land Area Within 100 km of Grid 99.5%
Average Proximity to Nearest Substation / Line 29 km
Urban Centers (>10,000 Population) 232
Total Urban Population 29.2 M
Prospective Resource Colocated Near Demand (>1M Pop) 52%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 21.8% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 24.5% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Uzbekistan across 11 standardized geothermal indicators

Uzbekistan Rank Global Peer Spread
Shallowest 200°C depth
4.5 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 50th percentile
Peak temp at 5 km
211.8 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 45th percentile
Prospective land area (>185°C at 5.5 km)
13.6% Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 23th percentile
Stored heat in-place (3-7 km)
127.7 ZJ Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 66th percentile
Typical geothermal gradient
33.2 °C/km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 47th percentile
Grid proximity (<50 km)
91.9% Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 92th percentile
Thin sediment coverage (<1 km)
15.4% Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 15th percentile
Curie isotherm depth
27.2 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 40th percentile
Moho crustal thickness
34.3 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 38th percentile
Model temperature uncertainty spread
±1 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 57th percentile
Urban demand colocation
30% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 88th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Uzbekistan?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Uzbekistan are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Uzbekistan

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Uzbekistan indicates sedimentary_rift geological controls governing subsurface heat transport, yielding 13.6% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Uzbekistan shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 91.9% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by sedimentary rift dynamics with median sediment thickness of 2.2 km and crustal thickness of 34.3 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 127.7 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Uzbekistan demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Uzbekistan is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 4 971 model cells (land area: 447 400 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier