TR-BM Europe Updated 2026-08-20

Turkey (Buyuk Menderes Graben) Geothermal Screening

Geothermal screening assessment identifies 16.1% prospective land reaching 185°C by 5.5 km depth in Turkey (Buyuk Menderes Graben).

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
16.1%

Primary baseline screening criterion

Shallowest Depth to 200°C Deep Target
5.2 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
231.8 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
42.3 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
92.6%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
27.9 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 4.5% 8.2% 12.3% 17.6% 21.5% 29.7%
175°C 3.5% 7% 9.6% 14.4% 19.5% 23.1%
200°C 2.3% 4.2% 7.3% 11.5% 14.3% 18.6%
225°C 1.5% 3% 5.4% 8.1% 9.2% 13%
250°C 0.8% 1.9% 3.3% 4% 5% 6.5%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
25 000 km² 100%
2 Reaches 185°C by 5.5 km
4 025 km² 16.1%
3 ...and within 50 km transmission
3 727 km² 14.9%
4 ...and within 100 km town
3 448 km² 13.2%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 8.1 km
Best 10th Percentile Depth to 200°C 6.3 km
Median Temperature at 5 km Depth 158.8 °C
Best 10th Percentile Temp at 5 km 207.7 °C
Median Sediment Thickness 1.6 km
Sediment / Hard-Rock Well Share 22.8%
Territory Under 1 km Sediment Cover 51%
Lithostatic Pressure at 5 km Depth 135 MPa
Moho Crustal Discontinuity Depth 30.9 km
Thermal Lithosphere Thickness 72.9 km
Curie Temperature Isotherm Depth 25.9 km
Model Temperature Spread Uncertainty (200°C) ±0.8 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 4 561 km
Land Area Within 25 km of Grid 80%
Land Area Within 50 km of Grid 92.6%
Land Area Within 100 km of Grid 97.8%
Average Proximity to Nearest Substation / Line 21.2 km
Urban Centers (>10,000 Population) 33
Total Urban Population 7.7 M
Prospective Resource Colocated Near Demand (>1M Pop) 60.1%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 25.8% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 29% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Turkey (Buyuk Menderes Graben) across 11 standardized geothermal indicators

Turkey (Buyuk Menderes Graben) Rank Global Peer Spread
Shallowest 200°C depth
5.2 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 40th percentile
Peak temp at 5 km
231.8 °C Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 53th percentile
Prospective land area (>185°C at 5.5 km)
16.1% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 27th percentile
Stored heat in-place (3-7 km)
27.9 ZJ Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 45th percentile
Typical geothermal gradient
42.3 °C/km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 60th percentile
Grid proximity (<50 km)
92.6% Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 93th percentile
Thin sediment coverage (<1 km)
51% Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 51th percentile
Curie isotherm depth
25.9 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Moho crustal thickness
30.9 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 44th percentile
Model temperature uncertainty spread
±1.7 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 77th percentile
Urban demand colocation
70.5% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 64th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Turkey (Buyuk Menderes Graben)?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Turkey (Buyuk Menderes Graben) are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Turkey (Buyuk Menderes Graben)

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Turkey (Buyuk Menderes Graben) indicates extensional_basin geological controls governing subsurface heat transport, yielding 16.1% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Turkey (Buyuk Menderes Graben) shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 92.6% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by extensional basin dynamics with median sediment thickness of 1.6 km and crustal thickness of 30.9 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 27.9 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Turkey (Buyuk Menderes Graben) demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Turkey (Buyuk Menderes Graben) is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 278 model cells (land area: 25 000 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier