TR-AE Europe Updated 2026-08-20

Turkey (Aegean Graben) Geothermal Screening

Geothermal screening assessment identifies 16.2% prospective land reaching 185°C by 5.5 km depth in Turkey (Aegean Graben).

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km Moderate
16.2%

Primary baseline screening criterion

Shallowest Depth to 200°C Deep Target
4.8 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
208.7 °C

Maximum modeled temperature

Typical Geothermal Gradient Elevated
42 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area High Accessibility
94%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
37.3 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 3.2% 7.2% 11.6% 13% 17.4% 25.2%
175°C 2.3% 5.7% 8.6% 11.7% 15.4% 16.6%
200°C 1.9% 4.1% 5.7% 7.7% 10.5% 12.4%
225°C 1.2% 2.2% 3.2% 4.3% 5.8% 6.6%
250°C 0.2% 0.5% 0.8% 1% 1.5% 1.8%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
85 000 km² 100%
2 Reaches 185°C by 5.5 km
13 770 km² 16.2%
3 ...and within 50 km transmission
12 944 km² 15.2%
4 ...and within 100 km town
11 779 km² 13.1%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 6.8 km
Best 10th Percentile Depth to 200°C 5.3 km
Median Temperature at 5 km Depth 145.3 °C
Best 10th Percentile Temp at 5 km 189.5 °C
Median Sediment Thickness 1.5 km
Sediment / Hard-Rock Well Share 41%
Territory Under 1 km Sediment Cover 43.8%
Lithostatic Pressure at 5 km Depth 139.3 MPa
Moho Crustal Discontinuity Depth 34.8 km
Thermal Lithosphere Thickness 87.7 km
Curie Temperature Isotherm Depth 25.9 km
Model Temperature Spread Uncertainty (200°C) ±1.4 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 9 481 km
Land Area Within 25 km of Grid 80.1%
Land Area Within 50 km of Grid 94%
Land Area Within 100 km of Grid 99.5%
Average Proximity to Nearest Substation / Line 24.2 km
Urban Centers (>10,000 Population) 102
Total Urban Population 13.4 M
Prospective Resource Colocated Near Demand (>1M Pop) 30.1%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 25.9% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 29.2% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Turkey (Aegean Graben) across 11 standardized geothermal indicators

Turkey (Aegean Graben) Rank Global Peer Spread
Shallowest 200°C depth
4.8 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 46th percentile
Peak temp at 5 km
208.7 °C Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Prospective land area (>185°C at 5.5 km)
16.2% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 27th percentile
Stored heat in-place (3-7 km)
37.3 ZJ Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 49th percentile
Typical geothermal gradient
42 °C/km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 60th percentile
Grid proximity (<50 km)
94% Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 94th percentile
Thin sediment coverage (<1 km)
43.8% Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 44th percentile
Curie isotherm depth
25.9 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 43th percentile
Moho crustal thickness
34.8 km Lower 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 37th percentile
Model temperature uncertainty spread
±1.6 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 65th percentile
Urban demand colocation
48.7% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 64th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Turkey (Aegean Graben)?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Turkey (Aegean Graben) are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Turkey (Aegean Graben)

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Turkey (Aegean Graben) indicates extensional_basin geological controls governing subsurface heat transport, yielding 16.2% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Turkey (Aegean Graben) shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 94% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by extensional basin dynamics with median sediment thickness of 1.5 km and crustal thickness of 34.8 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 37.3 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Turkey (Aegean Graben) demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Turkey (Aegean Graben) is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 944 model cells (land area: 85 000 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.