IT-72 Europe Updated 2026-08-20

Italy (Campanian Volcanic Zone) Geothermal Screening

Geothermal screening assessment identifies 47.8% prospective land reaching 185°C by 5.5 km depth in Italy (Campanian Volcanic Zone).

Key Geothermal Metrics

Land Reaching 185°C by 5.5 km High Potential
47.8%

Primary baseline screening criterion

Shallowest Depth to 200°C Shallow
3.2 km

Minimum drill depth for high enthalpy

Peak Temperature at 5 km Depth Commercial EGS
274.8 °C

Maximum modeled temperature

Typical Geothermal Gradient Volcanic / Rift
62.9 °C/km

Average to 5 km depth (15°C surface)

Grid Connectable Prospective Area Moderate Distance
79%

Hot territory within 50 km transmission

Stored Heat In-Place (3–7 km) 1 ZJ = 10²¹ Joules
67.4 ZJ

Thermal volume in place (>80°C baseline)

Depth vs. Temperature Matrix (% Land Area)

Proportion of national territory exceeding target isotherm at specified depth

0.1° Inversion Grid
Isotherm 3.0 km 4.0 km 5.0 km 6.0 km 7.0 km 8.0 km
150°C 17.2% 33.4% 46.4% 64.7% 84.8% 100%
175°C 12.8% 27.8% 44.6% 54.3% 81.6% 92.1%
200°C 9.5% 23.6% 34.6% 52.1% 69.6% 77.4%
225°C 8.1% 20% 28.8% 39.3% 53.2% 66.2%
250°C 5.1% 12.6% 22.9% 26.7% 42.2% 45.6%

4-Stage Geothermal Resource & Infrastructure Funnel

Progressive screening from gross national territory down to grid-connected & populated prospective zones

1 Whole country
13 590 km² 100%
2 Reaches 185°C by 5.5 km
6 496 km² 47.8%
3 ...and within 50 km transmission
5 132 km² 37.8%
4 ...and within 100 km town
4 742 km² 35.3%

Geological Setting & Subsurface Parameters

Lithology, basement thickness, stress and thermal boundary constraints

Median Depth to 200°C Isotherm 5.9 km
Best 10th Percentile Depth to 200°C 3.8 km
Median Temperature at 5 km Depth 217.5 °C
Best 10th Percentile Temp at 5 km 245.8 °C
Median Sediment Thickness 0.4 km
Sediment / Hard-Rock Well Share 12.8%
Territory Under 1 km Sediment Cover 78.4%
Lithostatic Pressure at 5 km Depth 139.4 MPa
Moho Crustal Discontinuity Depth 44.9 km
Thermal Lithosphere Thickness 118.6 km
Curie Temperature Isotherm Depth 16.6 km
Model Temperature Spread Uncertainty (200°C) ±1.3 km

Transmission Grid & Demand Colocation

Infrastructure interconnectivity and urban power demand proximity

High-Voltage Transmission Network Length 2 976 km
Land Area Within 25 km of Grid 66.3%
Land Area Within 50 km of Grid 79%
Land Area Within 100 km of Grid 88.8%
Average Proximity to Nearest Substation / Line 27.5 km
Urban Centers (>10,000 Population) 35
Total Urban Population 5.1 M
Prospective Resource Colocated Near Demand (>1M Pop) 53.1%

Target Sensitivity & Deep EGS Upside

Sensitivity of prospective resource area to adjusted depth and temperature thresholds

150°C Baseline at 5.5 km 76.5% of national territory reaches 150°C at 5.5 km depth
185°C Baseline at 7.5 km 86% of national territory reaches 185°C at 7.5 km depth

Global Peer Benchmarking (vs. 278 Assessed Jurisdictions)

Relative ranking distribution of Italy (Campanian Volcanic Zone) across 11 standardized geothermal indicators

Italy (Campanian Volcanic Zone) Rank Global Peer Spread
Shallowest 200°C depth
3.2 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 69th percentile
Peak temp at 5 km
274.8 °C Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 70th percentile
Prospective land area (>185°C at 5.5 km)
47.8% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 80th percentile
Stored heat in-place (3-7 km)
67.4 ZJ Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 57th percentile
Typical geothermal gradient
62.9 °C/km Top 10%
P0 (Lowest) P50 (Median) P100 (Highest) • 90th percentile
Grid proximity (<50 km)
79% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 79th percentile
Thin sediment coverage (<1 km)
78.4% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 78th percentile
Curie isotherm depth
16.6 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 63th percentile
Moho crustal thickness
44.9 km Lower 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 19th percentile
Model temperature uncertainty spread
±0.7 km Middle 50%
P0 (Lowest) P50 (Median) P100 (Highest) • 70th percentile
Urban demand colocation
74.4% Top 25%
P0 (Lowest) P50 (Median) P100 (Highest) • 84th percentile
Asset-Level 3D Simulation Available

Need Interactive 3D Spatial Inversion for Italy (Campanian Volcanic Zone)?

High-resolution 3D temperature cubes, localized Curie depth inversions, fault network stress tensors, and drilling capex curves for Italy (Campanian Volcanic Zone) are accessible through our Premium & Enterprise subscription tiers.

Direct Founder Contact: founders@geothermalradar.com

Analytical Geothermal Assessment & Discussion: Italy (Campanian Volcanic Zone)

Subsurface thermal interpretation, model uncertainty, infrastructure colocation, and resource quality analysis

Resource Overview

Geothermal assessment for Italy (Campanian Volcanic Zone) indicates volcanic_arc geological controls governing subsurface heat transport, yielding 47.8% of land area reaching the baseline target of 185°C at 5.5 km depth.

Uncertainty & Model Variance

Thermal inversion across Italy (Campanian Volcanic Zone) shows consistent model convergence with constrained standard deviations across deep crustal layers.

Grid & Infrastructure Colocation

National electrical transmission coverage positions approximately 79% of prospective geothermal ground within 50 km of existing high-voltage corridors.

Geological & Basement Setting

Subsurface lithology is characterized by volcanic arc dynamics with median sediment thickness of 0.4 km and crustal thickness of 44.9 km.

Stored Heat Volume

Accessible thermal energy in place between 3 km and 7 km depth above 80°C totals 67.4 Zettajoules (ZJ).

Peer Comparison

Benchmarked against 237 global assessment jurisdictions, Italy (Campanian Volcanic Zone) demonstrates competitive positioning across heat flow, infrastructure, and basement competence indicators.

Target Sensitivity Analysis

Screening at 150°C baseline at 5.5 km increases prospective territory, demonstrating substantial deep EGS resource headroom.

Screening Methodology, Parameters & Limitations

This screening assessment for Italy (Campanian Volcanic Zone) is generated from Geothermal Radar Data Pack 2026.1 utilizing global 0.1° hex-grid thermal inversion across 151 model cells (land area: 13 590 km²). Baseline prospective criterion is defined as reaching 185°C at or above 5.5 km depth with surface temperature normalized to 15°C.

  • Screening estimates represent regional-scale heat in place and do not replace localized 3D seismic or exploratory drilling.
  • Model uncertainties expand in regions with sparse deep boreholes and complex thrust fault kinematics.
  • Grid proximity indicators reflect line-of-sight distance to high-voltage transmission and do not account for local substation thermal capacity.
Need Detailed Asset-Level Due Diligence?

Access 3D temperature grids, drilling cost curves, and micro-siting GIS layers.

Request Full Technical Dossier